CONDO PHARMA

The Condo Pharma is a ducted laminar flow terminal housing for critical cleanroom and pharmaceutical applications, designed for zero air bypass. Built with a fully welded metal housing, it supports H13, H14, and U15 filters with GelSeal or gasket options. It offers room-side access, multiple diffuser types, and is fully leak tested for reliable, contamination-free performance.

Specifications

APPLICATION

Pharmaceutical, Biomedical, Microelectronics, Biotechnology, Microbiology, Research Labs, Food Industry, Nanotechnology, Nuclear Industry, LCD Manufacturing, Medical Device Fabrication, Semiconductor Fabrication, Aerospace, Healthcare

TYPE

Compact Mini-pleated Panel Filter

GRADE (EN 1822)

H13 / H14

FILTER MEDIA

Ultrafine Micro Glass Fiber / ePTFE

FRAME MATERIAL

Extruded Aluminum Anodized Profile / SS / G.I / Wooden

MAXIMUM TEMPERATURE

80°C — Continuous Operation

MAXIMUM RELATIVE HUMIDITY

90%

MOUNTING SYSTEM

Terminal Diffusers & Housings / Laminar Flow Systems

Advantages

The Condo Pharma is built to the most stringent no air-bypass construction standard for ducted laminar flow terminal modules — fully welded housing joints, seams, hanging tabs, and spigot connections, with every weld and penetration bubble tested to a zero leak criteria before the unit leaves the factory. This construction standard eliminates the possibility of unfiltered air bypassing the filter through housing leakage paths, which is the primary failure mode of bolted or unsealed terminal housing constructions in pharmaceutical and cleanroom validation environments. Filter installation and replacement is performed entirely from the room side by removing the diffuser, using quarter turn locks or quick clamping mechanisms with inbuilt gasket compression — removing the scheduling, contamination risk, and practical difficulty of above-ceiling filter change-out in active critical environments. The comprehensive range of optional features — volume control damper adjustable from room or ceiling side, pressure measurement and aerosol measurement port, aerosol injection port, aerosol dispersion system, mechanical rod damper control, DP switch filter replacement signalling, and pre-filter chamber — means the Condo Pharma can be configured to support the full suite of in-situ filter testing, airflow balancing, and performance monitoring activities required by pharmaceutical GMP qualification and cleanroom certification protocols, all accessible from the room side. The availability of perforated, swirl, adjustable vane, and 4-way diffusers in removable flush or hinged configurations ensures the correct room air distribution pattern is achieved for each application. RAL or epoxy corrosion-resistant finish across galvanised steel, mild steel, or stainless steel housing materials maintains hygienic surface integrity in pharmaceutical and high-humidity environments. Compatibility with both seamless PU gasket type and GelSeal type filters in H13, H14, and U15 grades completes a terminal module specification that addresses every aspect of critical environment laminar flow terminal filtration from supply to long-term validated operation.

Applications

  • Pharmaceutical
  • Biomedical
  • Microelectronics
  • Biotechnology
  • Microbiology
  • Research Labs
  • Food Industry
  • Nanotechnology
  • Nuclear Industry
  • LCD Manufacturing
  • Medical Device Fabrication
  • Semiconductor Fabrication
  • Aerospace
  • Healthcare

Technical Data

DataValue
CategoryTerminal HEPA Module-Replaceable HEPA type
Housing Box materialGalvanized steel or Mild Steel-Powder Coated /Stainless steel. Fully welded joints & Seams
FinishRAL finish in various grade/epoxy coated-to prevent corrosion
Diffuser / Face GuardRemovable flush type with SS nuts or Hinged type. Type-Perforated/Swirl/adjustable vane/4-way diffusers
Spigot connectionTop inlet or Side inlet
SpigotRibbed circular spigot or square inlet connection on top. Inlet connections are continuously welded.
Air Distribution Plate (Optional)Located at plenum inlet collar for uniform air distribution over filter air entry side. Plate made from SS/MS
Filter Installation & MountingEasily installed from room side by removing diffuser. Filter locking using quarter turn locks or quick clamping mechanisms with gasket compression inbuilt.
Volume Control Damper (Optional)Provided at spigot side for controlling airflow. Damper is room side adjustable or adjustable from ceiling side.
Pressure Measurement port cum Aerosol Measurement (optional)Measure filter replacement pressure drop at site & for upstream aerosol measurement
Aerosol Injection system (Optional)Separate port for Aerosol injection from room side
Damper Control system (Optional)Damper Operated from Room side by mechanical rod linkage
Aerosol Dispersion system (optional)For even dispersion of aerosol over filter face area
Pressure MonitoringDP switch for signaling filter replacement
Hanging TabsFully welded hanging tabs used for ceiling suspension. 10mm Ø hole is provided for hanging.
Housing Box Insulation (Option)Foil backed insulation-2” thick
Terminal Box HeightStandard height is 12”. Other Box height based on filter depths
Performance TestingEach terminal module shall be fully leak tested. All welds and penetrations shall be bubble tested for leaks and must meet zero leak criteria.
Pre-Filter (Optional)Additional chamber for Pre-Filter installation can be provided
HEPA FilterSeamless PU Gasket type or Gel Seal type. Please refer Hepa filter technical catalogue for selection.
HEPA Grade as per EN 1822H13/H14/U15
Maximum Pressure drop of filter450 Pa