We Separate Everything except Science from Technology

Solving Industrial Challenges with Wide Variety of Filtration Technology

Barotec : Delivering value and engineered solutions through filtration, your filtration distributor

OVERVIEW

Lorem Ipsum is simply dummy text of the printing and typesetting industry. Lorem Ipsum has been the industry’s standard dummy text ever since the 1500s, when an unknown printer took a galley of type and scrambled it to make a type specimen book.

Air Curtain Invisair MG

The INVISAIR air curtain is designed to be installed invisibly in false ceilings and columns or drawers around the door. It is an ideal solution for those entrances that for architectural reasons require an air curtain installation that is fully integrated into the interior design of the building.

Specifications

AIR CURTAINS

Combined

COMMUNICATION

Sigfox

OUTPUT

2x Analog

Description

Specially designed for applications where the body of the air curtain is to be installed inside a column or bulkhead for architectural reasons. It can be vertically or horizontally mounted. Self-supporting casing construction made of galvanized steel plate, finished in structural epoxy-polyester painting white colour RAL9016 as standard. Other colours or stainless steel are available on request. The air flow of Invisair follows a straight line from the air inlet grille to the to the discharge. Inlet area inside a bulkhead or column should be designed with suitable grille provided by others. Anodized aluminium outlet vanes, airfoil shaped, adjustable from 0 to 15º each side. Double-inlet centrifugal fans driven by an external rotor motor and low noise level. 5-speed selector. EC models assembled with very low consumption efficiency fans. “P” type with water heated coil. “E” type with electrical shielded elements, three stages with integrated regulation. “A” type without heating, air only. Optional expansion DX coil. Includes Plug&Play control with 7m RJ45 cable and infrared remote control. Optional: Clever control (programmable, automatic, intelligent, energy saving, Modbus RTU for BMS…)

Technical Data

ModelNominal Airflow
m³/h
Recommended Installation Height
m
IM 1500 A26402,5-3,5
IM 2000 A39602,5-3,5
IM 2500 A46202,5-3,5
IG 1500 A32003-4
IG 2000 A48003-4
IG 2500 A56003-4
IECG 1500 A36003-4,2
IECG 2000 A54003-4,2
IECG 2500 A63003-4,2
ModelNominal Airflow
m³/h
Electrical Heating Capacity 400Vx3
kW
Electrical Heating Capacity 460Vx3
kW
Electrical Heating Capacity 480Vx3
kW
Recommended Installation Height
m
IM 1500 E26404/8/12--2,5-3,5
IM 2000 E39606/12/18--2,5-3,5
IM 2500 E46206/12/18--2,5-3,5
IG 1500 E32007,5/15/22,5--3-4
IG 2000 E480010/20/30--3-4
IG 2500 E560010/20/30--3-4
IECG 1500 E36007,5/15/22,5--3-4,2
IECG 2000 E540010/20/30--3-4,2
IECG 2500 E630010/20/30--3-4,2
ModelNominal Airflow
m³/h
Heating Capacity 80/60ºC
kW
Heating Capacity 60/40ºC
kW
Heating Capacity 50/40ºC
kW
Recommended Installation Height
m
IM 1500 P642480-13,65-2,5-3,5
IM 1500 P86248014,23--2,5-3,5
IM 2000 P643720-19,7-2,5-3,5
IM 2000 P86372022,17--2,5-3,5
IM 2500 P644340-23,48-2,5-3,5
IM 2500 P86434027,69--2,5-3,5
IG 1500 P643000-15,47-3-4
IG 1500 P543000--16,373-4
IG 1500 P86300016,02--3-4
IG 2000 P644500-22,29-3-4
IG 2000 P544500--23,153-4
IG 2000 P86450024,92--3-4
IG 2500 P645250-26,61-3-4
IG 2500 P545250--28,763-4
IG 2500 P86525031,16--3-4
IECG 1500 P643400-16,77-3-4,2
IECG 1500 P543400--17,863-4,2
IECG 1500 P86340017,29--3-4,2
IECG 2000 P645100-24,14-3-4,2
IECG 2000 P545100--25,243-4,2
IECG 2000 P86510026,86--3-4,2
IECG 2500 P645950-28,84-3-4,2
IECG 2500 P545950--31,383-4,2
IECG 2500 P86595033,63--3-4,2
ModelNominal Airflow
m³/h
Recommended Installation Height
m
IECG 1500 A36003-4,2
IECG 2000 A54003-4,2
IECG 2500 A63003-4,2
ModelNominal Airflow
m³/h
Electrical Heating Capacity 400Vx3
kW
Electrical Heating Capacity 460Vx3
kW
Electrical Heating Capacity 480Vx3
kW
Recommended Installation Height
m
IECG 1500 E36007,5/15/22,5--3-4,2
IECG 2000 E540010/20/30--3-4,2
IECG 2500 E630010/20/30--3-4,2
ModelNominal Airflow
m³/h
Heating Capacity 80/60ºC
kW
Heating Capacity 60/40ºC
kW
Heating Capacity 50/40ºC
kW
Recommended Installation Height
m
IECG 1500 P643400-16,77-3-4,2
IECG 1500 P543400--17,863-4,2
IECG 1500 P86340017,29--3-4,2
IECG 2000 P645100-24,14-3-4,2
IECG 2000 P545100--25,243-4,2
IECG 2000 P86510026,86--3-4,2
IECG 2500 P645950-28,84-3-4,2
IECG 2500 P545950--31,383-4,2
IECG 2500 P86595033,63--3-4,2
ModelNominal Airflow
m³/h
Recommended Installation Height
m
IG 1500 A 60Hz UL COMP32003-4
IG 2000 A 60Hz UL COMP48003-4
IG 2500 A 60Hz UL COMP56003-4
IECG 1500 A 60Hz UL COMP36003-4,2
IECG 2000 A 60Hz UL COMP54003-4,2
IECG 2500 A 60Hz UL COMP63003-4,2
ModelNominal Airflow
m³/h
Recommended Installation Height
m
IG 1500 A 60Hz UL COMP32003-4
IG 2000 A 60Hz UL COMP48003-4
IG 2500 A 60Hz UL COMP56003-4
IECG 1500 A 60Hz UL COMP36003-4,2
IECG 2000 A 60Hz UL COMP54003-4,2
IECG 2500 A 60Hz UL COMP63003-4,2
ModelNominal Airflow
m³/h
Heating Capacity 80/60ºC
kW
Heating Capacity 60/40ºC
kW
Heating Capacity 50/40ºC
kW
Recommended Installation Height
m
IG 1500 P86 60Hz UL COMP300016.02--3-4
IG 2000 P86 60Hz UL COMP450024.92--3-4
IG 2500 P86 60Hz UL COMP525031.16--3-4
IECG 1500 P86 60Hz UL COMP340017.29--3-4,2
IECG 2000 P86 60Hz UL COMP510026.86--3-4,2
IECG 2500 P86 60Hz UL COMP595033.63--3-4,2
IG 1500 P64 60Hz UL COMP3000-15.47-3-4
IG 2000 P64 60Hz UL COMP4500-22.29-3-4
IG 2500 P64 60Hz UL COMP5250-26.61-3-4
IECG 1500 P64 60Hz UL COMP3400-16.77-3-4,2
IECG 2000 P64 60Hz UL COMP5100-24.14-3-4,2
IECG 2500 P64 60Hz UL COMP5950-28.84-3-4,2
IG 1500 P54 60Hz UL COMP3000--16.373-4
IG 2000 P54 60Hz UL COMP4500--23.153-4
IG 2500 P54 60Hz UL COMP5250--28.763-4
IECG 1500 P54 60Hz UL COMP3400--17.863-4,2
IECG 2000 P54 60Hz UL COMP5100--25.243-4,2
IECG 2500 P54 60Hz UL COMP5950--31.383-4,2

Related Products